ATS Panels
ATS panels provide automatic transfer between normal and emergency power sources where continuity of supply is important. Transfer logic, interlocking and power devices are selected according to the project operating philosophy.
The panels can be integrated with generator systems, local control circuits and the control signals required by the project power-management scheme.
Engineered around the requirements of each project
The final configuration is selected from project documents, operating philosophy, installation conditions and approved equipment requirements.
Typical Applications
Configurations
- Normal / emergency sources
- Auto / manual operation
- Transfer & retransfer logic
- Electrical / mechanical interlocking
- Generator start / stop interface
- Status & alarm signals
ATS engineering for reliable source transfer
An ATS is not simply two breakers. Source monitoring, transfer timing, interlocking, generator commands, retransfer conditions and manual operation must match the project operating philosophy.
Transfer Logic
Source monitoring, generator start, delay timing, transfer and return sequences defined for the application.
Interlocking & Safety
Mechanical/electrical interlocking prevents unintended source paralleling according to the selected architecture.
Power & Control
Breaker ratings, fault level, command circuits, signals and generator interface engineered together.
RFQ engineering checklist
- Normal/emergency source
- Rated current/fault level
- Generator interface
- Transfer logic
- Interlocking
- Auto/manual modes
Related technical reading
Use the technical knowledge base to review concepts that affect selection, protection and operation.
Technical specifications are defined from the actual project requirements
Final panel ratings and configuration — including rated current, short-circuit requirements, degree of protection, internal separation and major equipment — are confirmed after review of the approved project documents and operating requirements.
Questions commonly asked before an RFQ
Answers are intentionally engineering-focused; final ratings and configuration are determined from project documents.
ATS vs manual changeover?
ATS performs transfer automatically based on source conditions and control logic, while manual changeover depends on operator action.
Can the ATS start a generator?
In generator-backed systems, the ATS control logic can manage start/stop commands and readiness signals per project philosophy.
Is interlocking required?
Preventing unintended simultaneous connection of sources is a fundamental ATS design consideration; the method depends on equipment architecture.
Are transfer delays adjustable?
Detection, generator start, warm-up, transfer and return delays can be defined according to the selected control architecture.
What drives ATS panel price?
Rated current, source arrangement, breaker type, generator interface, fault level, transfer logic, operating modes and equipment brands are major factors.
Need this product family for your project?
Send project drawings and specifications so our engineering team can review the required configuration.