Medium-Voltage Switchgear Manufacturing
Tavazon Sanat medium-voltage switchgear is engineered for industrial switching, distribution, protection and metering. Each assembly is developed from the approved single-line diagram, rated voltage and current, fault duty, operating philosophy and maintenance requirements, so incoming, outgoing, bus-coupler and metering cubicles reflect the actual network duty.
Engineering coordinates the circuit breaker and switching devices, earthing functions, CT/VT, protection relays, metering circuits, mechanical and electrical interlocks, cable termination space and compartmentation as one system. The objective is safe operation, clear switching logic and maintainability in accordance with IEC 62271-200 and project-specific requirements through design, manufacturing, inspection and final testing.
20 kV ABB UniSec ring section
Design and manufacture of a 20 kV, 630 A ring section with a VD4 vacuum circuit breaker on the incomer.
View the UniSec projectAligudarz industrial distribution project
Design, manufacture and installation of ABB UniSafe withdrawable MV switchgear with two 630 A incomers and two outgoing feeders, alongside the LV distribution boards.
View the Aligudarz projectEPIL report for a 24 kV, 630 A panel
The report covers electrical and mechanical verification on the tested panel under IEC 62271-200:2021. It covers resistance, earthing continuity, continuous current, auxiliary and control circuits, and mechanical operation.
Use the report to review the scope of verification for this tested assembly. Confirm the documents and FAT requirements for your own project in the enquiry.
View EPIL test reportEngineered around the requirements of each project
The final configuration is selected from project documents, operating philosophy, installation conditions and approved equipment requirements.
Typical Applications
Configurations
- Incoming, outgoing & bus-coupler feeders
- Circuit breaker / switching devices & earthing
- CT / VT, protection relay & metering
- Mechanical & electrical interlocking
- Cable termination & compartmentation
- Project-specific cubicle arrangement
Key engineering considerations for MV switchgear
MV switchgear selection must coordinate voltage, current, fault level, bus architecture, circuit breaker, CT/VT, protection relay, interlocking, cable termination and maintenance philosophy from the approved SLD.
Cubicle & Bus Architecture
Incomer, outgoing, bus-coupler and metering arrangements coordinated with the network operating philosophy.
Protection & Interlocking
Breaker, earthing switch, CT/VT, protection relays and mechanical/electrical interlocks coordinated as one system.
Safety & Maintainability
Compartmentation, cable termination, service access, testing and IEC 62271-200 requirements considered during engineering.
RFQ engineering checklist
- MV SLD
- Rated voltage/current
- Fault level
- VCB & switching
- CT/VT & protection
- Interlocking & cables
Related technical reading
Use the technical knowledge base to review concepts that affect selection, protection and operation.
Choose a switchgear manufacturer by evidence, not by claims
TSP connects project engineering, independent test evidence, documented FAT and real project references so technical claims can be checked against actual records.
Project proof
Review projects that demonstrate the actual engineering and manufacturing scope of this product family.
Independent test evidence
External test records provide a direct technical evidence layer for the product family.
Related electrical systems
Related panel families are linked when they commonly form part of the same industrial power architecture.
Technical specifications are defined from the actual project requirements
Final panel ratings and configuration — including rated current, short-circuit requirements, degree of protection, internal separation and major equipment — are confirmed after review of the approved project documents and operating requirements.
Industrial project vendor qualification
Tavazon Sanat holds documented registration in the Ministry of Petroleum domestic manufacturers long vendor resources list for a related industrial electrical scope. Ask our team to confirm product category and current purchaser-specific eligibility for your project.
What determines MV switchgear pricing?
MV switchgear cost depends on rated voltage, cell count, circuit-breaker type, fault level, CT/VT, protective relays, earthing and interlocks, testing evidence and project specifications.
Attach an SLD or BOQ. For comparable quotations, include the switchgear lineup, system voltage, equipment ratings, approved vendors, delivery scope and FAT requirements.

EPIL — MV Switchgear Dielectric & Impulse Verification 24 kV / 630 A
EPIL dielectric verification of 24 kV / 630 A MV switchgear under IEC 62271-200:2021 covering power-frequency withstand, lightning impulse and auxiliary/control-circuit dielectric tests. Documented results are passed.

EPIL — MV Switchgear Electrical & Mechanical Verification 24 kV / 630 A
EPIL verification of 24 kV / 630 A MV switchgear under IEC 62271-200:2021 covering resistance measurements, earthed-metallic continuity, continuous-current testing, auxiliary/control current checks and mechanical operation. Documented results are passed.

EPIL — MV Metal-Enclosed Switchgear IP / IK 24 kV / 630 A
EPIL IP/IK verification of 24 kV / 630 A medium-voltage metal-enclosed switchgear with references to IEC 60529, IEC 62271-200 and IEC 62262. Documented results are passed.

EPIL — MV Conex IP / IK Verification
EPIL IP and IK verification for medium-voltage Conex equipment based on IEC 60529 and IEC 60068-2-75. Documented results are passed.
Questions commonly asked before an RFQ
Answers are intentionally engineering-focused; final ratings and configuration are determined from project documents.
What information is required for an MV switchgear RFQ?
The SLD, voltage level, rated current, fault level, cubicle schedule, protection philosophy, cable data and approved equipment are key inputs.
What is IEC 62271-200?
It is a key standard for AC metal-enclosed switchgear and controlgear above 1 kV. Project-specific requirements must still be reviewed.
How are VCB and protection relays selected?
Selection depends on network ratings, switching duty, protection philosophy, CT/VT requirements, fault level and the approved vendor list.
Can ABB-based architectures be supplied?
The platform and equipment must match approved project documents and availability. TSP has project experience with ABB MV architectures.
Which tests matter for MV panels?
Mechanical and functional checks, interlocks, control circuits, electrical tests and required documentation are reviewed per project scope.
Need this product family for your project?
Send project drawings and specifications so our engineering team can review the required configuration.